test

Stair flight decoupling with transverse force rods for force transmission

Stair securing dowels serve to absorb horizontal loads at the stair base.
The stainless steel dowel element is potted into the floor slab and is decoupled with an acoustic bearing to avoid sound bridges.
In combination with a horizontal stair bearing, the vertical load at the stair base is transmitted to the floor slab.

Rules (de)

Properties

Impact sound insulated joint
Joint is suitable for standard fire resistant classes